Skip to content

DataFlux Func (Automata)

After successfully activating DataFlux Func (Automata), Func is automatically deployed on a cloud host. In the Workspace, you can also use Integration to quickly log in to the corresponding Func platform.

Supported Sites

Site Login URL
Asia Pacific 1 (Singapore) https://ap1-auth.truewatch.com/
Asia Pacific 2 (Singapore) https://ap2-auth.truewatch.com/
Indonesia 1 (Jakarta) https://id1-auth.truewatch.com/
Africa 1 (South Africa) https://za1-auth.truewatch.com/

One-Click Activation

Click DataFlux Func (Automata) to begin the activation process:

Permissions and Billing
  • Each Workspace can only have one Func activated; only the Owner has the permission to activate and configure it.
  • DataFlux Func (Automata) is billed monthly. One month's fee is deducted in a lump sum immediately after activation succeeds, and the next month's fee is automatically deducted on the expiration date (for example, if activated on 04/13, the charge is made on 04/13, then on 05/13, and so on...).
  1. Go to the Overview page and click Activate.
  2. Fill in the domain name and select the specification required by the application.
  3. Click Activate Now.
  4. In the agreement pop-up window, click OK to successfully activate DataFlux Func (Automata).

The automated deployment process is expected to take 10-15 minutes. After activation is complete, you can directly Enter Console from Integration > Func > Extended Applications. Click Configuration > Overview to view related information about DataFlux Func (Automata).

After DataFlux Func (Automata) is activated, refer to the following if you need to modify configuration information:

Modify the Access Domain

  1. Click Modify.
  2. Obtain and enter the email verification code.
  3. Click OK to complete identity verification, and then you can modify the current domain.
Note

The access domain can be modified 3 times per day.

Modify Specification

  1. Click Modify.
  2. Obtain and enter the email verification code.
  3. Click OK to complete identity verification, and then you can modify the current specification.
Note

After the specification is modified, it takes effect immediately on the same day, and billing starts according to the new specification. The old specification will be directly discarded, and no refund will be issued.

Status

On the DataFlux Func (Automata) configuration page, you can view the current application status.

Your application may have the following five states:

State Description
Activating Indicates that the one-click activation of Func (Automata) is in progress.
Activated Indicates that the one-click activation of Func (Automata) has been completed.
Plan Changing Indicates that the access domain or specification is being modified.
Upgrading Indicates that the current application service is being upgraded.
Operation Failed Indicates that an operation issue occurred during the activation process. You can click View Error Feedback or directly contact us.

Deactivate Application

  1. Click Deactivate Application.
  2. Obtain and enter the email verification code.
  3. Click OK to complete identity verification, and the confirmation page will open. You can view the application expiration date.

DataFlux Func (Automata) is billed on a monthly basis. Before the expiration date, you can still use the Func service, and you can also Reactivate it as needed.

Application Expiration

There are two possible scenarios:

  • Deactivate on your own: If you choose to deactivate the application yourself, the system will automatically deactivate it after expiration.

  • Insufficient balance: Three days before the application is charged upon expiration, the system checks whether the balance is sufficient for renewal. If the balance is insufficient, the system sends an email and an in-system notification to the Workspace Owner. After expiration, the hosted application will be automatically released. If you have used DataFlux Func (Automata) before and reactivate the application before expiration, all application data can be restored. However, if the renewal is not completed in time, the data will be permanently deleted.

In both scenarios above, the system will retain your data for the last 7 days. Within these 7 days, if you activate the application again, you can choose to restore all data or not to restore data.

  • Restore data: Back up the previously retained data to the newly activated Func.
  • Do not restore data: Discard all previous data and reactivate the application.

Self-Monitoring Data

In general, when DataFlux Func is used frequently, the volume of content data such as metrics and logs may be quite large. In this case, you can enable self-monitoring data reporting.

For more details, see How to Configure DataFlux Func Self-Monitoring Data.

DataFlux Func Deployment Plan

For information about the DataFlux Func Deployment Plan, see:

For detailed content about DataFlux Func deployment and maintenance manuals, script development manuals, script marketplace, and more, see: